У нас законно все » Программы » GibbsCAM 2012+ Build 10.3.13.0

 

GibbsCAM 2012+ Build 10.3.13.0

Автор: azon584 от 15-11-2012, 20:26, посмотрело: 528

0
GibbsCAM 2012+ Build 10.3.13.0


Gibbs and Associates, разработчик GibbsCAM программного обеспечения для программирования станков с ЧПУ, объявила о выпуске последней версии GibbsCAM программирования ЧПУ.

Called GibbsCAM 2012+, this new version includes tremendous speed and performance improvements, including a rendering option specifically geared for multi-axis parts, improved cutting strategies and many productivity enhancements. The new version includes improvements for all levels of GibbsCAM, including the Mill and Lathe Production, SolidSurfacer, Radial Milling, MTM and 5-Axis options.

GibbsCAM 2012+ includes a Multi-Axis Rendering option free of charge with each seat of the software. Formerly a $2,000 option, Multi-Axis Rendering provides significant accuracy improvements for rotary milling applications, especially when displaying toolpaths with continuous changes in both tool position and orientation. Improved gouge and tool interference checking for tilting tools shows customers programming errors before they become costly mistakes on the shop floor.

"We are pleased to be able to offer our customers such a valuable option free of charge,” says Bill Gibbs, President and CEO of Gibbs and Associates and Cimatron North America. “A picture may be worth a thousand words, but being able to catch a tool collision before it gets to the shop floor can save customers thousands of dollars.”

To boost speed and productivity for all GibbsCAM users, the GibbsCAM 2012+ rendering engine takes full advantage of multi-core and multi-threaded computer hardware to drastically boost processing speed. Part rendering speed is now up to 33 times faster, depending on specific computer hardware and part complexity. Increased rendering speed saves programming time and reduces programming costs.

Improvements to Radial Milling include the ability to produce a smooth, unsegmented, helical toolpath, which takes advantage of native machine-based linear and circular interpolation capabilities. The benefits of this type of toolpath include vastly simplified post processor output, potential savings of hundreds of lines of G-code, and reduced machining time. Also included are new cutting strategies for parts with open-sided pockets, very thin walls, shallow cut areas and a highly efficient G-code program. In addition, material only clean-up areas provide customers with optimized toolpaths.

What's fixed in GibbsCAM 2012+ version 10.3.13.0:
0319 WCU-28811-328 10.3.13 Fix: Resolved an issue that caused a particular part file to crash while right mouse clicking on the FlashCPR palette.
28998 ITS-38159-392 10.3.12 Fix: Resolved an issue that caused incorrect data when exporting a DXF file.
29761 10.3.12 Post: Resolved an issue in the Post Engine that prevented the commands "CalcZSurf#" and "CalcCP2FmSurf#" from working properly.
29986 WMH-46928-316 10.3.12 Fix: Resolved an issue that caused FlashCPR to crash when rendering an MTM part with a particular "Grip Z" value.
30015 GBQ-33337-713 10.3.12 Fix: Resolved an issue that caused incorrect edge data when increasing the tolerance for extracting to geometry.
30096 UQL-81369-535 10.3.12 Fix: Resolved an issue that caused GibbsCAM to crash when redoing a Lathe Roughing operation.
30159 10.3.12 Update: Implemented a command to the macros that will run the Auto Wizard while in the Hole Manager.
30207 10.3.12 Post: Resolved an issue that prevented the Post Engine commands: "StartPosX#", "StartPosY#", and "StartPosZ" from working properly.
30279 10.3.12 Post: Resolved an issue in the Post Engine where the "CalcCAng" and "CalcSCAng" should have been ignored by ABCToolPath operations.
30292 BKL-83378-366 10.3.12 Fix: Resolved an issue that caused GibbsCAM to crash when attempting to post process.
29169 10.3.11 Fix: Resolved an issue that prevented the Tooltips from displaying inside the Operation Manager.
29206 10.3.11 Fix: Resolved an issue that caused the "FirstHomeIsMachineHome" boolean to return false when it should have been true.
29883 10.3.11 Fix: Resolved an issue that caused the post processor to not segment spiral toolpath correctly.
29904 XMH-65184-933 10.3.11 Fix: Resolved an issue that caused the Japanese version to incorrectly display the diameter and degree symbols.
29959 BEH-87673-436 10.3.11 Update: Implemented a command to the macros that will open the view palette.
29964 BAI-88755-928 10.3.11 Fix: Resolved an issue that prevented the GibbsCAM Macros from defining Lathe form tools.
29977 10.3.11 Fix: Resolved an issue that caused a particular post processer to generate "PostRandomReadFeat" error message.
29994 VUS-21524-932 10.3.11 Fix: Resolved an issue that prevented a tapping operation from retracting to the proper height before positioning to second group of holes.
29995 10.3.11 Fix: Resolved an issue that caused a difference in the posted output when changing the "Graphic Part Face Dist" value.
30009 IHZ-92996-478 10.3.11 Fix: Resolved an issue that caused GibbsCAM to crash during MTM Simulation when the "Auto Tool Size" option was enabled.
30068 ZAL-39884-985 10.3.11 Fix: Resolved an issue that caused GibbsCAM to print the color black in the graphic display regions that contained dimensions and text.
30073 BLR-73143-771 10.3.11 Fix: Resolved an issue that caused EDM to produce an Internal System Error during post processing when the datum's were set with a zero material thickness.
30089 SHR-14946-114 10.3.11 Fix: Resolved an issue that caused EDM to generate an incorrect exit move in the toolpath.
8103 10.3.10 Fix: Resolved an issue that caused the Profiler using a relatively large part, to go into an infinite loop.
29172 10.3.10 Fix: Resolved an issue that caused a 5-axis drilling operation to produce an error when the "Retract to feed distance" was enabled.
29316 LQW-77797-444, AXZ-79941-434, GHE-39814-192, ULR-58294-968, PAR-38329-483, MTA-41565-369, QND-52515-341, UBU-55158-896 10.3.10 Fix: Resolved an issue that caused GibbsCAM to crash when attempting to print with OpenGL enabled.
29822 10.3.10 Fix: Resolved an issue that prevented the "Reverse" function in the MDD Editor for B-axis tool display to not output the correct angular value.
29889 10.3.10 Post: Resolved an issue that prevented the post engine from outputting the correct "Inverse Time Feedrate" for B-axis Turning operations.
29892 SCV-61235-373 10.3.10 Fix: Resolved an issue that caused the 5-axis module to load incorrect data when opening multiple process dialogs.
29928 GMM-92375-729 10.3.10 Fix: Resolved an issue that caused a Milling operation to produce complete toolpath rather than material only toolpath.
29944 JGL-18761-319 10.3.10 Fix: Resolved an issue that caused warnings in the Advanced 3D dialog when the stepover field inadvertently was set to zero.
29564 TBU-31277-235 10.3.9 Fix: Resolved an issue in the French language that caused edit fields in the FlashCPR palette to be clipped.
29836 XTH-47582-563 10.3.9 Fix: Resolved an issue that prevented a Mill Pocketing operation from producing "Material Only" toolpath.
28948 ZRJ-21934-544 10.3.8 Fix: Resolved an issue that caused overlapping text fields in the Face Milling dialog.
29114 131758 10.3.8 Fix: Resolved an issue that prevented an EDM 4-axis part from synchronizing properly.
29230 LDT-29636-739 10.3.8 Fix: Resolved an issue that caused the 5-axis module to produce "RandomReadFeature" errors when attempting to open or redo operations.
29303 10.3.8 Fix: Resolved an issue that caused a 5-axis operation to produce an error that the selected tool was invalid when using a solid body as the tool holder.
29389 WNH-63246-137 10.3.8 Fix: Resolved an issue that prevented Custom Drill Cycles from utilizing the parameter for CW or CCW arcs.
29453 RNV-97438-567 10.3.8 Fix: Resolved an issue that prevented the GibbsCAM Reporter from displaying the Insert Information.
29639 JJP-61356-764 10.3.8 Fix: Resolved an issue that caused GibbsCAM to crash when redoing a Mill Contour operation that was using the generation 3 function.
29653 HXH-28625-659 10.3.8 Fix: Resolved an issue that caused GibbsCAM to crash when enabling the "Material Only" function.
29654 TMU-55777-812 10.3.8 Fix: Resolved an issue that caused GibbsCAM to crash when attempting to use the "Stay In Stock" option.
29670 MTQ-87291-113 10.3.8 Fix: Resolved an issue that prevented a custom 5-axis drilling process from rendering and post processing a peck drilling operation.
29677 SBZ-75536-985 10.3.8 Fix: Resolved an issue that caused GibbsCAM to crash when the balloons were enabled and the cursor hovered over the mill retracts function.
29822 10.3.8 Fix: Resolved an issue that prevented correct functionality in the MDD Editor for the "Reverse" checkbox for the B-Axis tool rotation display.
29161 10.3.7 Post: Resolved an issue that caused the post processor to not produce out-of-plane arcs properly.
29194 10.3.7 Post: Resolved an issue that prevented the post processor from outputting B-axis Turning arc motion.
29580 YCX-93436-574 10.3.7 Fix: Resolved an issue that caused a dramatically slower launch of GibbsCAM.
29586 10.3.7 Fix: Resolved an issue that prevented Lathe Form Tool profiles from getting set properly via the API.
29068 HJU-71734-226 10.3.6 Fix: Resolved an issue with the Profiler that caused the system to crash when the Spun Outline option was enabled.
29333 GYC-83691-213 10.3.6 Fix: Resolved an issue that caused false collisions during FlashCPR rendering when using a Custom Holder.
29346 10.3.6 Fix: Resolved an issue that caused the 5-axis module to crash when running the Finnish GibbsCAM version on an English Operating System.
29350 YVC-74985-216 10.3.6 Fix: Resolved an issue that prevented GibbsCAM 32-bit from loading the VoluMill module under the Windows XP Operating System.
29262 10.3.5 Fix: Resolved an issue in the Czech language that displayed chopped off text strings in the "Anonymous Usage Statistics" dialog.
29263 10.3.5 Fix: Resolved an issue in the Czech language that prevented two radio buttons from getting displayed in the "5-axis Multi Blade" dialog.
29266 DIA-37582-568 10.3.5 Fix: Resolved an issue that was causing the system font to display very large, which prevented the rotate tab from getting displayed on the Milling dialog.
29078 KZB-97779-557 10.3.4 Fix: Resolved an issue that will automatically adjust the "Top Surface Z" value for pre GibbsCAM v2012+ part files containing a thread mill tool used by a contouring operation.
29214 10.3.4 Fix: Resolved an issue that was ignoring the "Work Area Limit" that was set for the B-axis.
29176 DWX-28662-584, DKM-25841-949 10.3.3 Fix: Resolved an issue that was causing PostHASTE to produce an "Undefined Error Message".
29212 GKU-51133-763 10.3.3 Fix: Resolved an issue that caused the system to crash upon loading a part file that contained toolpath with no associated geometry.
29157 YAS-58427-258 10.3.2 Fix: Resolved an issue that caused a slow launch of GibbsCAM, primary experienced in foreign language versions.
28951 ZRK-83698-657 10.3.1 Fix: Resolved an issue that caused Machine Simulation to take a considerable amount of time to render the stock.
29054 KNM-92682-563, KNM-92682-563 10.3.1 Fix: Resolved an issue that was causing a phantom tool during rendering while the part body was highlighted and the stock was set to transparent.
29040 10.3.1 Fix: Resolved an issue that prevented the Wire EDM module from registering and from running.
29065 HJJ-23838-567 10.3.1 Fix: Resolved an issue that prevented Machine Simulation from detecting tool holder collisions.
29073 MDR-34353-145 10.3.1 Fix: Resolved an issue that prevented the GibbsCAM Reporter from generating a part image on 32-bit systems.
28846 10.3.0 Fix: Resolved an issue that caused the Advanced 3D module to crash when redoing a specific combination of machining processes.
28895 10.3.0 Update: Updated the SafeNet USB SuperPro/UltraPro drivers; which may require a system restart.
28903 HQI-72446-296 10.3.0 Fix: Resolved an issue that caused a Mill Pocketing operation to generate toolpath in unselected and unrelated areas.
28869 EGW-12749-115 10.2.33 Fix: Resolved an issue that caused incorrect process dialog data for 5-axis operations when using the GibbsCAM preference "Open Process Dialog on Op Load".
28876 REP-43492-816 10.2.33 Fix: Resolved an issue in the Classroom edition of GibbsCAM that prevented the Autodesk Inventor add-in from transferring the part to GibbsCAM.
28882 NKG-81972-743 10.2.33 Fix: Resolved an issue that prevented FlashCPR from rendering a MTM Mill Contour operation when the tool radius was defined with an invalid parameter.
28848 PUH-82913-563, FDN-77726-968 10.2.32 Fix: Resolved an issue that caused GibbsCAM to hang or crash when attempting to print a solid model or a rendered image.
28879 10.2.32 Fix: Resolved an issue that caused GibbsCAM to crash upon closing FlashCPR when both the profiler and the machining markers were running.
22779 UQJ-57936-974 10.2.31 Update: Implemented the request to modify the German Master PDF so that the references to GibbsCAM are changed to Virtual Gibbs.
28789 MTQ-87291-113 10.2.31 Fix: Resolved an issue that in some instances prevented drill peck operations from outputting the correct g-code, and from rendering this peck motion.
28797 LGX-67679-515 10.2.31 Fix: Resolved an issue that caused a custom mill tool holder to disengage the tool from the holder during FlashCPR rendering.
28825 FJT-38837-898 10.2.31 Fix: Resolved an issue that caused missing surfaces during the import of an Autodesk Inventor file.
28839 ZXH-51995-426 10.2.31 Fix: Resolved an issue that caused Wire EDM to produce a warning on the GibbsCAM 32-bit verson, that the rendering could not be started.
28643 VYE-27919-239 10.2.30 Fix: Resolved an issue that caused the system to lockup when redoing a particular 5-axis operation.
28787 REL-52512-552 10.2.30 Fix: Resolved an issue in the post engine that caused an incorrect feedrate for a rigid tapping operation.
28343 MCS-94885-276 10.2.29 Fix: Resolved an issue in Macros that caused the "tool face relief" to get loaded into the "diameter relief" field.
28733 10.2.29 Update: Updated the Radial Contour Process library to v5.08.02.
28748 HKE-65121-881 10.2.29 Fix: Resolved an issue that caused the Profiler to generate the wrong Lathe shape when using the Spun Outline.
28646 10.2.28 Update: Implemented sorting commands to the GibbsCAM "Macros" and "API's".
27372 10.2.28 Update: Implemented two new items into the Pathfinder plugin for "Macros" and "Custom Drill Cycles".
28502 DUP-45427-789 10.2.28 Fix: Resolved an issue that caused the "Shrink Wrap Visible" shortcut to be inaccessible in the German version.
28526 DUP-45427-789 10.2.28 Fix: Resolved an issue with inaccessible shortcut keys in the German version.
28597 DSH-96963-962 10.2.28 Fix: Resolved an issue that caused Solid Edge assembly files to lose their part relationship depending on whether the file was imported into a Lathe or Mill part environment.
28607 DSH-96963-962 10.2.28 Fix: Resolved a few localization issues in Virtual Gibbs and the German version of GibbsCAM.
28617 FSF-72715-911 10.2.28 Fix: Resolved an issue that prevented the GibbsCAM Preferences from displaying the correct path to a custom "Font" directory.
28658 PBM-44885-412 10.2.28 Fix: Resolved an issue that prevented a Thread Mill tool from generating the correct toolpath to produce a chamfer.
28662 10.2.28 Update: Implemented a post processor command to check the OpMode of the next tool being used.
28669 UUA-95268-917 10.2.28 Fix: Resolved an issue that caused a Runtime error when attempting to open a specific STL model file.
28673 HKE-65121-881 10.2.28 Fix: Resolved an issue that caused the GibbsCAM Profiler to generate an incorrect Lathe profile when using the "Spun Outline".
28706 QIW-36641-765 10.2.28 Fix: Resolved an issue that caused incomplete GibbsCAM STL models when importing these files into another system.
28710 10.2.28 Update: Updated GibbsCAM to support Autodesk 2013 RealDWG files.
28715 10.2.28 Fix: Resolved an issue in Compost that caused incorrect inch-metric conversion when using an inch part with a metric post, or vice versa.
28719 CJT-58697-395 10.2.28 Fix: Resolved an issue that caused Machine Simulation to produce incorrect lathe spindle rotations while machining 5-axis operations.
28438 CTK-26294-841 10.2.27 Fix: Resolved an issue where the Spanish translation had not been implemented for all GibbsCAM Reporters.
28504 10.2.27 Update: Implemented the Parasolid v25 library into GibbsCAM v10.2.x channel.
28559 10.2.27 Post: Resolved an issue in the post engine that provides an option for filtering nested comments.
28561 JTA-84765-742 10.2.27 Fix: Resolved two issues, one that caused an incomplete mill rest material operation, and second caused poor plunge locations into the material.
28562 HTW-28174-119 10.2.27 Fix: Resolved an issue that caused the Tool Manager to display a non-applicable value for lathe form tool lengths.
28565 10.2.27 Post: Resolved an issue in the post engine that caused consecutive post processing to a particular file to produce different output.
28580 10.2.27 Fix: Resolved an issue that prevented the installation of the CimatronE Add-In.
28617 FSF-72715-911 10.2.27 Fix: Resolved an issue that prevented the GibbsCAM Preferences from displaying the correct path to a custom "Font" directory.
28620 PBB-62214-485 10.2.27 Fix: Resolved an issue that prevented FlashCPR and Machine Simulation from appearing on the dropdown menu when running under Windows XP.
28626 EXD-45589-991 10.2.27 Fix: Resolved an issue that caused lengthy coordinate system comments to crash the system.
28649 10.2.27 Update: Implemented an updated library containing new functionality for the 4-axis "Radial Contour Process".
28498 NPY-65385-971 10.2.26 Fix: Resolved a localization issue in FlashCPR for the German language.
28511 10.2.26 Fix: Resolved an issue so that the ability to use the function "Use Op Start" is consistent between FlashCPR and Machine Simulation.
28513 IDB-55817-655 10.2.26 Fix: Resolved an issue that caused Mill Roughing to produce unexpected toolpath when defining fixtures and using the "trim to material" function.
28518 10.2.26 Fix: Resolved an issue that caused a Lathe Plunge Roughing operation to gouge the part profile.
27939 UMQ-89758-996 10.2.25 Update: Implemented the ability for a macro command to lock the Utility Markers.
27973 CEX-52636-667 10.2.25 Update: Implemented the ability for the GibbsCAM Reporter to contain the name of the solid used for the tool holder.
28356 MMF-35154-155 10.2.25 Fix: Resolved an issue that prevented a Mill Contour operation from cutting sequentially from start point to end point.
28401 10.2.25 Update: Updated the libraries for the 5-axis module to v2012-04.
28403 QKP-41787-713 10.2.25 Fix: Resolved an issue that caused FlashCPR to display unusual results when the tool was defined with insufficient flute length or insufficient tool length from holder.
28419 10.2.25 Fix: Resolved an issue that caused the 5-axis module to generate a small cuboid while processing a operation.
28432 10.2.25 Update: Implemented a change to the CAD Add-Ins for the SolidWorks title so that it is apparent that it supports files of 2011 and newer.
28443 10.2.25 Update: Implemented Multi-Axis Roughing to the 5-axis module.
26673 THE-32455-262 10.2.24 Fix: Resolved an issue that prevented a Mill Contouring operation from producing a final pass around a spiral shape.
27658 10.2.24 Fix: Resolved an issue that prevented the EDM module from producing toolpath when using a custom strategy.
27828 UYW-84353-359 10.2.24 Fix: Resolved an issue that caused fields in the GibbsCAM Reported to display incorrect values.
28229 KCY-34878-246 10.2.24 Fix: Resolved an issue that prevented creating a tangent line at a specific location on a circle.
28254 BXM-35425-417 10.2.24 Fix: Resolved an issue that caused the Hole Manager AFR function to incorrectly recognize through holes as blind holes.
28261 10.2.24 Post: Resolved an issue in the Post Engine that caused incorrect polarity of the retract level when drilling holes on the sup-spindle.
28264 10.2.24 Fix: Resolved two issues with the Japanese language regarding missing input fields inside the EDM module.
28280 AWW-19246-498 10.2.24 Fix: Resolved an issue that caused an offsetting error when generating Mill Pocketing toolpath.
28286 EHS-22688-579 10.2.24 Fix: Resolved an issue that prevented Mill Contouring from generating a complete toolpath if the start and end markers were overlapping.
28314 NYG-83926-859 10.2.24 Post: Resolved an issue in the Post Engine that caused the "StartPosY" and "StartPosY#" to output incorrectly.
28352 FPI-22368-735 10.2.24 Fix: Resolved an issue in the 5-axis module that caused the system to crash when using a custom tool holder.
28359 LLZ-54967-859 10.2.24 Fix: Resolved an issue in the 5-axis module that caused the system to generate a stock body if that process for any reason would fail.
26622 GXA-86639-588 10.2.23 Fix: Resolved an issue that caused FlashCPR to render an MTM Lathe operation from the lower turret rather then the upper turret.
28094 10.2.23 Post: Resolved an issue in the Post Engine that caused incorrect approach moves when the "SetUseOpCS" mode was not in effect.
28193 PRY-76456-732 10.2.23 Fix: Resolved an issue that prevented 5-axis drilling operations from applying the rapid retract option.
28225 10.2.23 Update: Implemented functionality by using a macro that will automatically adjust the stock size when applying shrink wrap.
28236 YBW-57542-317 10.2.23 Fix: Resolved an issue that prevented Mill Pocketing from producing toolpath when applying a part body, stock body and fixture body.
28241 TLN-37264-286 10.2.23 Fix: Resolved an issue that prevented Lathe Utility Templates from producing operations.
28272 40685 10.2.23 Fix: Resolved an issue that would prevent Mill Pocketing from producing a complete toolpath when the part body was intersected by a fixture body.
28276 PVW-52335-914 10.2.23 Fix: Resolved an issue that prevented the toolpath from avoiding the fixture body when the part contained a stock body.
...................................................more...................................

Please note that this is not a complete list of all fixes, but a list of items you may have some interest in.

About Gibbs and Associates

Since our founding in 1982, we have been a leader in providing cutting-edge CAD/CAM technology while maintaining its signature ease-of-use and productivity increasing qualities. William F. Gibbs started the company in an effort to bring NC programming services to the greater Los Angeles area at a time when many households had not even seen a desktop computer. Just two years later, we introduced our Gibbs System (inspired by the Macintosh graphical interface) leading the way in the development of CAD/CAM software.

GibbsCAM 2012+ Build 10.3.13.0


Год: 2012
Язык: английский
Таблетка: присутствует
Размер: 2.35 Gb

Скачать GibbsCAM 2012+ Build 10.3.13.0

Теги: GibbsCAM 2012


Категория: Программы

Уважаемый посетитель, Вы зашли на сайт как незарегистрированный пользователь.
Мы рекомендуем Вам зарегистрироваться либо войти на сайт под своим именем.
Информация
Посетители, находящиеся в группе Гости, не могут оставлять комментарии к данной публикации.