SIMATIC HMI оптимизирован в соответствии с конкретными интерфейсами человек-машина и использует открытые и стандартизированные интерфейсы оборудования и программного обеспечения, которые позволяют эффективно интегрироваться в вашей системе автоматизации.
HMI software: One-stop visualization software
With their product families SIMATIC WinCC (TIA Portal), SIMATIC WinCC and SIMATIC WinCC Open Architecture SIMATIC HMI covers the whole range of Engieering and Visualization Software for the Human Machine Interface.SIMATIC WinCC (TIA Portal), the successor of WinCC flexible can be used to configure nearly all SIMATIC operator devices.The functional scope comprises visualization tasks close to the machine as well as SCADA applications on PC-based multi-user systems.
For process visualization tasks of highest complexity and SCADA applications e.g. with redundant architectures and vertical integration up to Plant Intelligence solutions SIMATIC WinCC in its current version 7 is the right choice.
WinCC Open Architecture at last adresses solutions with highly customer specific adaptation requirements and specialised functions even on Non-Windows platforms.
WinCC Basic
• WinCC Projects:
- Migration of licenses with up to 512 archive tags
- Opening the WinCC project after the update from WinCC V7.0 SP2 to WinCC V7.0 SP3
- Opening the WinCC Explorer on PCs with Spanish operating systems
- Import of texts from a text list via the Text Distributor
• Graphics Designer:
- Checking the specified limits in an I/O field
• Tag Logging:
- WinCC OnlineTrendControl: Persistence settings are maintained
- WinCC OnlineTrendControl: Acyclical logging of the changes with hysteresis
- WinCC OnlineTrendControl: Performance when displaying dashed trends
• Alarm Logging:
- WinCC AlarmControl: Display of the info text
- WinCC AlarmControl: Application of filter criteria
- WinCC AlarmControl: System message display on Asian WinCC systems
• Archive System:
- Database segments stay connected after Runtime is activated
• Cross Reference:
- Linking tags in functions that are in subdirectories
• Global Script / ANSI-C:
- Picture change via the "OpenPrevPicture" function on a client without its own project
• VB-Script:
- VBS Editor: Intellisense functionality when WinCC Controls prior to WinCC V7 are accessed
- Call of the "ActiveScreen" method
• Basic Process Control:
- Group display: Display of the "Message type" in the "Object properties" dialog of
customized objects
- Background color of the area buttons on a client without its own project
- Message window: Filter according to time of day in the operation list and in the process list
• Runtime:
- Stability at picture change if the process picture contains an incorrectly configured
connector
- Stability of the application "pdlrt.exe"
- Virtual keyboard: Key combination
- Display of faceplates after picture change
- Appearance of the Radio-Box and the Check-Box
- The user privileges are evaluated at the mouse event "release right button"
- Reset of the button status "pressed" after the appearance is changed to "invisible"
Client-Server System:
- Stability of the server during Runtime
• Redundant System:
- Runtime stability when using the TELEPERM M channel
- Deactivating a project and shutting down a computer via ODK functions (see 2.2.1)
• OS Compilation:
- Appearance of faceplates in the correct layer of a process picture
• ODK:
- Time stamp for the ODK function "MSRTGetSelectedMsg()"
WinCC Channels
• OPC Channel:
- OPC-DA: Correct display of the quality code "GOOD"
- OPC-DA: Application of write jobs corresponding to the configured update cycle
• Allen Bradley - Ethernet IP:
- Writing binary tags
WinCC/DataMonitor
• Excel Workbook:
- Evaluation of the time section during export of archive tags
WinCC/WebNavigator
• Web Client:
- Web Viewer "WinCCViewerRT": Call of the configuration dialog
- WinCC OnlineTrendControl: Addition of archive tags with server prefix
WinCC Basic
• WinCC Projects:
- Performance during autostart
- Editing of WinCC projects in SIMATIC Manager on PCs without a connection to the domain
- Error message no longer displayed when SIMATIC Manager is opened after a restart
of the PC
- WinCC ServiceMode: Name resolution during configuration of the WinCC ServiceMode
• User Administration:
- SIMATIC Logon: Display of login dialog after the deactivation and activation of a project
• Graphics Designer:
- Multiple rewiring of tags
- Multi-line text is saved in the faceplate instance
• Alarm Logging:
- Status tag for group messages
• Report System:
- Printing reports: Speed for reports that contain a WinCC control
- Printing reports: No control character at line breaks in static text
• Archive System:
- Message when the storage capacity on the hard drive is insufficient
• Runtime:
- Virtual keyboard: Key combination under Windows 7 and Server 2008 R2
- Stability of the application "pdlrt.exe" when closing picture windows
- Ressource consumption of the application "pdlrt.exe" at picture change
- No blockage on the client when an operator input message is created
- Operation of text lists with transparent backgrounds
• Load Online Changes:
- After message numbers have been changed, a download of online changes is
no longer possible
• Redundant System:
- No duplicate display of messages
• OS Complete Upload:
- Complete upload of a multiclient that was started with AutostartRT
• ODK:
- "PWGenCheckUser()" function evaluates the user/password combination correctly
WinCC Channels
• OPC Channel:
- Reconnect after connection disruption on the WinCC-OPC-HDA Server
WinCC/DataMonitor
• Excel Workbook:
- Evaluation of the time section during export of archive tags
WinCC/WebNavigator
• Web Client:
- Client installation on PCs with Windows 7 possible without interaction
- Adjustment of the size of picture windows in runtime
- Display of trend names in Trend control
- Modification of faceplate tags when authorization number 1002 "Web access - monitoring
only" is set
About Siemens AG Siemens AG is a German engineering conglomerate, the largest of its kind in Europe. Siemens has international headquarters located in Berlin, Munich and Erlangen. The company has three main business sectors: Industry, Energy, and Healthcare; with a total of 15 divisions. Worldwide, Siemens and its subsidiaries employ approximately 420,800 people in nearly 190 countries and reported global revenue of 76.651 billion euros for the year of 2009. Siemens AG is listed on the Frankfurt Stock Exchange, and has been listed on the New York Stock Exchange since March 12, 2001.
Название: Siemens Simatic WinCC 7.0 SP3
Версия: Update 1 and Update 2
Интерфейс: multilanguage
ОС: Windows XP 32bit / Seven / Server 2008 64bit
Системные требования: WinCC V7.0 SP3 or at least one option of WinCC V7.0 SP3.
Размер: 2.8 Gb
Скачать Siemens Simatic WinCC 7.0 SP3 Update 1 and Update 2